Data from a number of tables included in the report is given below.
Urban Sealed Surface Lives
Asset | Sample (no.) | Lowest (years) | Highest (years) | Average (years) | Median (years) |
---|---|---|---|---|---|
Normal Use Hotmix | 11 | 20 | 30 | 26 | 25 |
High Use Hotmix | 8 | 18 | 28 | 22 | 21 |
Normal Use Spray Seal | 13 | 13 | 30 | 20 | 20 |
High Use Spray Seal | 7 | 15 | 22 | 18 | 20 |
Normal Use Cold Overlay | 8 | 10 | 25 | 16 | 15 |
High Use Cold Overlay | 3 | 7 | 16 | 13 | 15 |
Urban Sheeted Lives
Asset | Sample (no.) | Lowest (years) | Highest (years) | Average (years) | Median (years) |
---|---|---|---|---|---|
Township Sheeted | 9 | 5 | 20 | 15 | 15 |
Rural Sealed Surface Lives
Asset | Sample (no.) | Lowest (years) | Highest (years) | Average (years) | Median (years) |
---|---|---|---|---|---|
Normal Use Hotmix | 3 | 19 | 26 | 23 | 25 |
High Use Hotmix | 2 | 16 | 26 | 21 | 21 |
Normal Use Spray Seal | 2 | 16 | 30 | 22 | 20 |
High Use Spray Seal | 1 | 15 | 20 | 17 | 16 |
Normal Use Cold Overlay | 6 | 16 | 19 | 17.5 | 17.5 |
High Use Cold Overlay | 6 | 16 | 16 | 16 | 16 |
Rural Sheeted Surface Lives
Asset | Sample (no.) | Lowest (years) | Highest (years) | Average (years) | Median (years) |
---|---|---|---|---|---|
Rural Arterial (Poor Material) | 2 | 5 | 13 | 9 | 9 |
Rural Arterial (Good Material) | 6 | 10 | 20 | 15 | 14 |
Rural Collector (Poor Material) | 3 | 5 | 24 | 12 | 8 |
Rural Collector (Good Material) | 7 | 12 | 27 | 18 | 15 |
Rural Local (Poor Material) | 3 | 6 | 19 | 12 | 10 |
Rural Local (Good Material) | 7 | 15 | 35 | 23 | 20 |
Rural Track (Poor Material) | 4 | 10 | 24 | 16 | 15 |
Rural Track (Good Material) | 3 | 30 | 55 | 38 | 30 |
Road Pavements
Asset | Sample (no.) | Lowest (years) | Highest (years) | Average (years) | Median (years) |
---|---|---|---|---|---|
Normal Use | 11 | 50 | 100 | 77 | 80 |
Heavy Use | 10 | 20 | 60 | 47 | 50 |
Footpaths
Asset | Sample (no.) | Lowest (years) | Highest (years) | Average (years) | Median (years) |
---|---|---|---|---|---|
Block Paved | 12 | 10 | 50 | 43 | 50 |
Insitu Concrete | 13 | 20 | 50 | 44 | 50 |
Hotmix | 12 | 20 | 50 | 29 | 28 |
Spray Seal | 8 | 10 | 50 | 23 | 20 |
Crusher Dust | 10 | 10 | 50 | 19 | 50 |
Kerb & Gutter
Asset | Sample (no.) | Lowest (years) | Highest (years) | Average (years) | Median (years) |
---|---|---|---|---|---|
Upright Kerb & Gutter | 12 | 40 | 75 | 65 | 70 |
Median Kerb | 11 | 30 | 75 | 59 | 70 |
Valley Drain | 10 | 40 | 75 | 65 | 70 |
Stormwater
Asset | Sample (no.) | Lowest (years) | Highest (years) | Average (years) | Median (years) |
---|---|---|---|---|---|
RCP | 8 | 50 | 100 | 89 | 100 |
FRC Pipe | 4 | 80 | 100 | 96 | 100 |
uPVC | 5 | 20 | 100 | 70 | 80 |
Box Culvert | 6 | 50 | 100 | 73 | 75 |
SEP | 4 | 50 | 80 | 60 | 55 |
Junction Box | 4 | 50 | 80 | 60 | 55 |
Headwall | 5 | 50 | 80 | 58 | 50 |
Lined Channel | 4 | 50 | 100 | 78 | 80 |
Unlined Channel | 4 | 10 | 100 | 78 | 100 |
Community Wastewater Management System (CWMS)
Asset | Sample (no.) | Lowest (years) | Highest (years) | Average (years) | Median (years) |
---|---|---|---|---|---|
Earthernware Gravity Pipe | 2 | 50 | 50 | 50 | 50 |
PVC Gravity Pipe | 2 | 50 | 50 | 50 | 50 |
PVC Rising Main Pipe | 2 | 50 | 50 | 50 | 50 |
Pump Chamber | 3 | 30 | 100 | 60 | 50 |
Pump | 3 | 30 | 50 | 43 | 50 |
Pump Mechanical & Electrical | 3 | 25 | 50 | 35 | 30 |